Every Connector job that runs on our servers is subject to a maximum run time limit of 120 seconds. 

This ensures that all customers receive equal and fair use of our server resources, maintains our infrastructure cost sustainability, and also safeguards against cases where unreasonably large PDF outputs may impact surrounding services.

When a Connector job reaches the 120-second time limit, it will exit immediately and raise a “Failed to complete in the allotted time of 120 seconds” error in your Notifications area and in the Form entry’s Connector logs.

Reasons for hitting the 120-second time limit

1. Size, complexity, and other issues with your Excel/Word template

Every page/worksheet and every field, formula, or other syntax in your Word/Excel template has to be scanned, evaluated, and executed by our template engine.

So if your Excel file has many worksheets or your Word template spans many pages, then it will take longer for our platform to generate an output.
In the case of Excel, having long chains of dependent Excel formulae can also slow generation.

Any links to network drives or other “file/folder” references in your Word/Excel template will cause our template engine to try accessing these unreachable file paths, which will delay processing by a number of seconds. 

2. Size and complexity of your Form design

If your Form design consists of hundreds or thousands of fields, then this will take more resources to load and execute as part of the template generation process.  
Repeatable pages and Table fields, in particular, can greatly increase generation time, since these can be populated with many repeated sets of fields if you don’t limit the maximum number of repeats that a user can capture.

3. Form entry-specific factors

Two key factors to consider are the number of images and the number of repeated rows captured on the specific Form entries that fail.

Every image that is included in the template output consumes server memory and other resources during the generation process, which slows the overall execution time of the connector job.

Similarly, if the user captures many repeated rows of data, this will slow generation as the template engine needs to loop through these repeats and generate accordingly.

4. The type of file to output

Generating a PDF from a Word/Excel template involves almost twice the amount of processing since our platform must first generate the template as Excel/Word and then convert that file into a PDF.
So there are two steps to the creation of a custom PDF output, while there is just one step to generate an Excel/Word output.
Similarly, generating CSV, text, JSON or XML outputs take different amounts of time, but as a whole are usually much faster than a PDF, Word or Excel output.

Why do some entries generate and others time out for the same Form design?

You may also find that some entries for a specific Form design will generate PDFs just fine, but others fail.  
In these cases, your template and Form design combination was likely already close to hitting timeout issues, and the failing entries have just that little bit more data (field answers, images), which pushes the template generation over the time limit.  
Additionally, these “on the edge” connector jobs are more likely to timeout during peak load times when server resources are at their highest utilisation.  “Edge” jobs running during off-peak times have a higher chance of success since the platform generally has more server resources available.

How to resolve timeout issues

We have no plans to increase the timeout period for Connector jobs, for the reasons given earlier.

So if you’re hitting timeout problems, then you need to change your Form design, template, and specific entry scenarios to address the root causes above.

Below are some suggestions about how to avoid hitting our timeout limits:

  • Reduce the complexity of your Word/Excel template to have:
    • fewer pages/worksheets, 
    • fewer formulae/dynamic syntax
    • fewer images included from Form entries
  • Check your template for any links to network drives or other such file path references, and remove any you find
  • Remove any floating text fields from your Excel templates – these are not supported and are known to delay generation.
  • Limit the maximum number of repeats by setting a maximum repeat range in the Form design, especially those that contain Media (image) fields.
  • Simplify your Form design to have fewer fields and thus a smaller Form entry dataset.
  • Split your Form design such that the images/repeated data are uploaded over multiple form entries.
  • Split your template into multiple template files and have multiple connectors to generate each smaller template separately.

I’ve tried the suggestions and my Connectors still don’t run in under 120 seconds 

If you still can’t get your template to generate within the 120-second limit, then ask our support team for help.

It’s possible our support personnel can spot an optimisation or tweak to your template which reduces the runtime substantially.

    • Related Articles

    • Form Connector – Email

      One of the most common requirements is to send custom emails and files containing form-captured data to key people when a form is submitted. For example, a building inspection is performed, and a ‘Certificate of Inspection’ needs to be emailed to the ...
    • Form Connector – REST

      This Connector will be interesting if you have access to technical personnel (software developers) and want to tightly integrate with our platform. The REST Connector will automatically send form entry data in XML or JSON format to your specific web ...
    • Form Connector – QuickBooks

      Our platform lets you easily add and quickly configure a one-way synchronization of form-captured data to QuickBooks. After adding and authenticating a QuickBooks Connection, QuickBooks Form Connectors can be added to Data Entry Forms to push data ...
    • Form Captured Date & Time Values

      Forms can capture Date, Time, or combined Date/Time data for each record. Date only or Time only fields Date only and Time only fields are captured in the local device time, but without any timezone information. As such these are always displayed as ...
    • Date and Time values in Form entries

      Dates and times are captured as follows on form entries: Date only and Time only fields are captured in the local device time, but without any timezone information. As such, these are always displayed as the raw, local time values, without any time ...